Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Orthop Trauma Surg ; 144(5): 2327-2335, 2024 May.
Article in English | MEDLINE | ID: mdl-38653837

ABSTRACT

BACKGROUND: Despite advancements in total knee arthroplasty (TKA), 10-20% of patients remain dissatisfied after surgery. Improved anteroposterior (AP) stability provided by medial pivot (MP) implants may theoretically lead to higher patient satisfaction. METHODS: AP stability and patient-reported outcome measures (PROMs) at one-year postsurgery were compared between patients who underwent TKA with MP- (n = 121), posterior stabilized (PS; n = 53) and rotating platform (RP; n = 57) implants in a double-blind multicentre randomized controlled trial (Dutch Trial Register: NL6856, 21-02-2018). AP stability was assessed at 30°, 60° and 90° of knee flexion using a KT-2000 arthrometer. PROMs were measured preoperative and one-year postsurgery. RESULTS: MP-TKA provided significant better AP stability at early flexion (30°) compared to PS- and RP-TKA (median [IQR]; 1.79 [1.14-2.77] mm vs. 3.31 [2.51-4.08] mm vs. 2.82 [1.80-4.03] mm, p < 0.001). Additionally, MP-TKA provided significant better AP stability at mid-flexion (60°) compared to PS-TKA (1.75 [1.23-2.36] mm vs. 2.14 [1.49-2.83] mm, p = 0.014). PROM improvements were comparable between implant designs. AP laxity of ≥ 4 mm at early flexion was independently of implant design associated with significantly worse Kujala scores. The incidence of ≥ 4 mm AP laxity at any knee angle was however not significantly different between implant designs. CONCLUSION: MP-, PS- and RP-TKA all provide excellent and comparable results. Although MP-TKA provided better AP stability at early flexion compared to PS- and RP-TKA, this was found to be unrelated to improved PROMs in favour of MP-TKA. More studies focusing on early and mid-flexion performance based differences between MP and other TKA designs are required to confirm our findings. Other non-implant related factors may play a more important role in the performance of TKA and are potentially worthwhile examining.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient Reported Outcome Measures , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Double-Blind Method , Male , Aged , Female , Middle Aged , Range of Motion, Articular , Prosthesis Design , Knee Joint/surgery , Knee Joint/physiopathology , Patient Satisfaction , Joint Instability/surgery , Joint Instability/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...